<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>grooved chipboard Archives - The Underfloor Heating Site</title>
	<atom:link href="https://theunderfloorheatingsite.co.uk/product-tag/grooved-chipboard/feed/" rel="self" type="application/rss+xml" />
	<link>https://theunderfloorheatingsite.co.uk/product-tag/grooved-chipboard/</link>
	<description></description>
	<lastBuildDate>Tue, 12 May 2026 16:05:40 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://theunderfloorheatingsite.co.uk/wp-content/uploads/2026/04/cropped-favicon-32x32.png</url>
	<title>grooved chipboard Archives - The Underfloor Heating Site</title>
	<link>https://theunderfloorheatingsite.co.uk/product-tag/grooved-chipboard/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>FlowDeck36 &#8211; Foiled Chipboard With 8mm Fleece &#8211; 16mm Pipe &#8211; 2400mm x 600mm x 30mm</title>
		<link>https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/22mm-foiled-chipboard-underfloor-heating-overlay-boards-with-8mm-resilient-fleece-2400mm-x-600mm-x-22mm-for-16mm-pipe-150mm-centres-full-tg4/</link>
		
		<dc:creator><![CDATA[Chris Thompson]]></dc:creator>
		<pubDate>Fri, 27 Jun 2025 14:05:32 +0000</pubDate>
				<guid isPermaLink="false">https://theunderfloorheatingsite.co.uk/?post_type=product&#038;p=1020758</guid>

					<description><![CDATA[<p>[block id="reso-chipboard-generic-important-message"]</p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/22mm-foiled-chipboard-underfloor-heating-overlay-boards-with-8mm-resilient-fleece-2400mm-x-600mm-x-22mm-for-16mm-pipe-150mm-centres-full-tg4/">FlowDeck36 &#8211; Foiled Chipboard With 8mm Fleece &#8211; 16mm Pipe &#8211; 2400mm x 600mm x 30mm</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1>22mm Foiled Chipboard Underfloor Heating Overlay Boards With 8mm Resilient Fleece &#8211; 2400mm x 600mm x 30mm &#8211; For 16mm Pipe &#8211; 150mm or 200mm Centres &#8211; Full TG4 &#8211; FlowDeck36 Foiled</h1>
<h2>Underfloor Heating Boards &#8211; grooved chipboard for underfloor heating 22mm pre routed</h2>
<ul>
<li><strong>Tongue and groove for faster installation all the way around &#8211; true TG4</strong></li>
<li><strong>22mm P5 Moisture Resistant Chipboards Foil Coated</strong></li>
<li><strong>8mm Resilient Fleece layer bonded underneath</strong></li>
<li><strong>1.44m2 Per Board for use with 16mm Pipe Only </strong></li>
<li><strong>Routed with 150mm or 200m centres</strong></li>
<li><strong>Feed pipes typically run underneath</strong></li>
<li><strong>A 6mm cement backer board must bonded to the Chip Board Panel before fitting finished floors &#8211; <span style="color: #ff6600;">Sold Separately</span></strong></li>
</ul>
<p>Moisture resistant routed chipboard, available standard, foiled, or bonded to additional thermal or acoustic insulation. Our Chip-UFH Board is highly conductive which allows for an even spread of heat throughout the floor. System should be completed with Overlay Board or suitable plywood, further details available on request. The board size is 1200mm x 600mm x 22mm, being grooved on one face as required to suit 12mm diameter underfloor heating pipes, with radius returns as standard.<br />
<strong>INSTALLATION</strong> Chip-UFH Board is typically installed directly onto floor joists (usually insulated in-between), utilising standard chipboard screws and joint adhesive.<br />
<strong>FINISHING</strong> An Overlay Board or suitable plywood should be applied prior to the application of any floor finishes. Overlay Board is installed as a floating floor, plywood should be installed using suitable fixings. Laminates, hardwood flooring and carpets should be applied using a suitable underlay as per manufactures instructions.<br />
<strong>SUITABLE FOR</strong> Chip-UFH Board is suitable for new build or retro fit installations, and the standard pattern board is normally available from stock.</p>
<p><strong style="color: #ff9900; font-size: 14.4px;">MINIMUM ORDER 15 BOARDS</strong></p>
<p><span style="color: #f99b1c;"><strong>PLEASE NOTE: DELIVERY OF THESE BOARDS MAY TAKE 3-4 WORKING DAYS</strong></span></p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/22mm-foiled-chipboard-underfloor-heating-overlay-boards-with-8mm-resilient-fleece-2400mm-x-600mm-x-22mm-for-16mm-pipe-150mm-centres-full-tg4/">FlowDeck36 &#8211; Foiled Chipboard With 8mm Fleece &#8211; 16mm Pipe &#8211; 2400mm x 600mm x 30mm</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FlowDeck36 &#8211; Chipboard With 8mm Fleece &#8211; 16mm Pipe &#8211; 2400mm x 600mm x 30mm</title>
		<link>https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/22mm-chipboard-underfloor-heating-overlay-boards-with-8mm-resilient-fleece-2400mm-x-600mm-x-22mm-for-16mm-pipe-150mm-centres-full-tg4/</link>
		
		<dc:creator><![CDATA[Chris Thompson]]></dc:creator>
		<pubDate>Fri, 27 Jun 2025 14:02:10 +0000</pubDate>
				<guid isPermaLink="false">https://theunderfloorheatingsite.co.uk/?post_type=product&#038;p=1020757</guid>

					<description><![CDATA[<p>[block id="reso-chipboard-generic-important-message"]</p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/22mm-chipboard-underfloor-heating-overlay-boards-with-8mm-resilient-fleece-2400mm-x-600mm-x-22mm-for-16mm-pipe-150mm-centres-full-tg4/">FlowDeck36 &#8211; Chipboard With 8mm Fleece &#8211; 16mm Pipe &#8211; 2400mm x 600mm x 30mm</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1>22mm Chipboard Underfloor Heating Overlay Boards With 8mm Resilient Fleece &#8211; 2400mm x 600mm x 30mm &#8211; For 16mm Pipe &#8211; 150mm or 200mm Centres &#8211; Full TG4 &#8211; FlowDeck36 Un-Foiled</h1>
<h2>Underfloor Heating Boards &#8211; grooved chipboard for underfloor heating 22mm pre routed</h2>
<ul>
<li><strong>Tongue and groove for faster installation all the way around &#8211; true TG4</strong></li>
<li><strong>P5 Moisture Resistant Chipboards</strong></li>
<li><strong>8mm Resilient Fleece layer bonded underneath</strong></li>
<li><strong>1.44m2 Per Board for use with 16mm Pipe Only </strong></li>
<li><strong>Routed with 150mm or 200mm centres</strong></li>
<li><strong>Feed pipes typically run underneath</strong></li>
<li><strong>A 6mm cement backer board must bonded to the Chip Board Panel before fitting finished floors &#8211; <span style="color: #ff6600;">Sold Separately</span></strong></li>
<li><strong>Options for foiled and bonded thermal or acoustic insulation</strong></li>
</ul>
<p>Moisture resistant routed chipboard, available standard, foiled, or bonded to additional thermal or acoustic insulation. Our Chip-UFH Board is highly conductive which allows for an even spread of heat throughout the floor. System should be completed with Overlay Board or suitable plywood, further details available on request. The board size is 1200mm x 600mm x 22mm, being grooved on one face as required to suit 16mm diameter underfloor heating pipes, with radius returns as standard.<br />
<strong>INSTALLATION</strong> Chip-UFH Board is typically installed directly onto floor joists (usually insulated in-between), utilising standard chipboard screws and joint adhesive.<br />
<strong>FINISHING</strong> An Overlay Board or suitable plywood should be applied prior to the application of any floor finishes. Overlay Board is installed as a floating floor, plywood should be installed using suitable fixings. Laminates, hardwood flooring and carpets should be applied using a suitable underlay as per manufactures instructions.<br />
<strong>SUITABLE FOR</strong> Chip-UFH Board is suitable for new build or retro fit installations, and the standard pattern board is normally available from stock.<br />
<span style="color: #f99b1c;"><strong><br />
</strong></span></p>
<p><strong style="color: #ff9900; font-size: 14.4px;">MINIMUM ORDER 15 BOARDS</strong></p>
<p><span style="color: #f99b1c;"><strong>PLEASE NOTE: DELIVERY OF THESE BOARDS MAY TAKE 3-4 WORKING DAYS</strong></span></p>
<p><span style="color: #f99b1c;"><strong> </strong></span></p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/22mm-chipboard-underfloor-heating-overlay-boards-with-8mm-resilient-fleece-2400mm-x-600mm-x-22mm-for-16mm-pipe-150mm-centres-full-tg4/">FlowDeck36 &#8211; Chipboard With 8mm Fleece &#8211; 16mm Pipe &#8211; 2400mm x 600mm x 30mm</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Acoustic Foiled Underfloor Heating Chipboard Pre-Routed 22mm thick 600mm wide plus 8mm Bonded Rubber Base Layer</title>
		<link>https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/foiled-chipboard-underfloor-heating-overlay-boards-db-acoustic-2400mm-x-600mm-x-30mm-for-16mm-pipe-full-tg4/</link>
		
		<dc:creator><![CDATA[Chris Thompson]]></dc:creator>
		<pubDate>Mon, 25 Nov 2024 12:32:25 +0000</pubDate>
				<guid isPermaLink="false">https://theunderfloorheatingsite.co.uk/?post_type=product&#038;p=1014630</guid>

					<description><![CDATA[<p>[block id="reso-chipboard-generic-important-message"]</p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/foiled-chipboard-underfloor-heating-overlay-boards-db-acoustic-2400mm-x-600mm-x-30mm-for-16mm-pipe-full-tg4/">Acoustic Foiled Underfloor Heating Chipboard Pre-Routed 22mm thick 600mm wide plus 8mm Bonded Rubber Base Layer</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Underfloor Heating Boards &#8211; grooved chipboard for underfloor heating 22mm pre routed</h2>
<ul>
<li><strong>Tongue and groove for faster installation all the way around &#8211; true TG4</strong></li>
<li><strong>P5 Moisture Resistant Chipboards</strong></li>
<li><strong>Bonded with 8mm ResoRubber base layer to the underside for acoustic sound deadening</strong></li>
<li><strong>1.44m2 Per Board for use with 12mm or 16mm Pipe Only </strong></li>
<li><strong>Routed with 150mm or 200m centres</strong></li>
<li><strong>Feed pipes typically run underneath</strong></li>
<li><strong>Options for foiled and bonded thermal or acoustic insulation</strong></li>
</ul>
<p>Moisture resistant routed chipboard, available standard, foiled, or bonded to additional thermal or acoustic insulation. Our Chip-UFH Board is highly conductive which allows for an even spread of heat throughout the floor. System should be completed with Overlay Board or suitable plywood, further details available on request. The board size is 1200mm x 600mm x 22mm, being grooved on one face as required to suit 12mm diameter underfloor heating pipes, with radius returns as standard.</p>
<p><strong>INSTALLATION</strong> Chip-UFH Board is typically installed directly onto floor joists (usually insulated in-between)</p>
<p><strong>FINISHING</strong> An Overlay Board or suitable plywood should be applied prior to the application of any floor finishes. Overlay Board is installed as a floating floor, plywood should be installed using suitable fixings. Laminates, hardwood flooring and carpets should be applied using a suitable underlay as per manufactures instructions.</p>
<p><strong>SUITABLE FOR</strong> Chip-UFH Board is suitable for new build or retro fit installations, and the standard pattern board is normally available from stock.</p>
<p><span style="color: #f99b1c;"><strong>PLEASE NOTE: DELIVERY OF THESE BOARDS MAY TAKE 3-4 WEEKS</strong></span></p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/foiled-chipboard-underfloor-heating-overlay-boards-db-acoustic-2400mm-x-600mm-x-30mm-for-16mm-pipe-full-tg4/">Acoustic Foiled Underfloor Heating Chipboard Pre-Routed 22mm thick 600mm wide plus 8mm Bonded Rubber Base Layer</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Plain Underfloor Heating Chipboard Pre-routed 22mm thick 600mm wide</title>
		<link>https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/plain-underfloor-heating-chipboard-pre-routed/</link>
		
		<dc:creator><![CDATA[Chris Thompson]]></dc:creator>
		<pubDate>Mon, 10 Jun 2024 00:00:00 +0000</pubDate>
				<guid isPermaLink="false">https://theunderfloorheatingsite.co.uk/?post_type=product&#038;p=1016001</guid>

					<description><![CDATA[<p>[block id="16mm-chipboard-short-description"]</p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/plain-underfloor-heating-chipboard-pre-routed/">Plain Underfloor Heating Chipboard Pre-routed 22mm thick 600mm wide</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Underfloor Heating Boards &#8211; grooved chipboard for underfloor heating 22mm pre routed</h2>
<ul>
<li><strong>Tongue and groove for faster installation all the way around &#8211; true TG4</strong></li>
<li><strong>P5 Moisture Resistant Chipboards</strong></li>
<li><strong>1.44m2 Per Board for use with 12mm or 16mm Pipe Only </strong></li>
<li><strong>Routed with 150mm or 200m centres</strong></li>
<li><strong>Feed pipes typically run underneath</strong></li>
<li><strong>A 6mm cement board must be glued and screwed as per manufacturers instruction to bring back structural strength before fitting finished floors</strong></li>
<li><strong>Options for foiled and bonded thermal or acoustic insulation</strong></li>
</ul>
<p><strong>Technical Data:</strong></p>
<ul>
<li><strong>Thermal Conductivity</strong>: 0.033 W/mK (when bonded to XPS)</li>
<li><strong>Moisture Absorption:</strong> 0.6%</li>
<li><strong>Widths Available:</strong> 600mm</li>
<li><strong>Lengths Available:</strong> 1200mm / 2400mm</li>
<li><strong>Dimensional Tolerances:</strong> (+/-1mm)</li>
<li><strong>Compressive Strength:</strong> 300kPa, 500kPa</li>
</ul>
<p>Moisture resistant routed chipboard, available standard, foiled, or bonded to additional thermal or acoustic insulation. Our Chip-UFH Board is highly conductive which allows for an even spread of heat throughout the floor. System should be completed with 6mm cement backer board, further details available on request.</p>
<p><strong>INSTALLATION</strong> Chip-UFH Board is typically installed directly onto floor joists (usually insulated in-between), utilising standard chipboard screws and joint adhesive.</p>
<p><strong>FINISHING</strong> A 6mm cement overlay board should be applied using co-polymer eva glue and screws prior to the application of any floor finishes. Laminates, hardwood flooring and carpets should be applied using a suitable underlay as per manufactures instructions. LVT type flooring normally requires a 2-3mm levelling compound applied to the cement backer board to smooth out join lines and screw heads.</p>
<p><strong>SUITABILITY </strong>Chip-UFH Board is suitable for new build or retro fit installations, and the standard pattern board is normally available from stock.</p>
<p><span style="color: #f99b1c;"><strong>PLEASE NOTE: DELIVERY OF THESE BOARDS MAY TAKE 3-4 WORKING DAYS</strong></span></p>
<p>&nbsp;</p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/plain-underfloor-heating-chipboard-pre-routed/">Plain Underfloor Heating Chipboard Pre-routed 22mm thick 600mm wide</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Foiled Underfloor Heating Chipboard Pre-Routed 22mm thick 600mm wide</title>
		<link>https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/foiled-chipboard-underfloor-heating-overlay-boards-1200mm-or-2400mm-x-600mm-x-22mm-for-12mm-or-16mm-pipe-full-tg4/</link>
		
		<dc:creator><![CDATA[Chris Thompson]]></dc:creator>
		<pubDate>Sun, 09 Jun 2024 00:00:00 +0000</pubDate>
				<guid isPermaLink="false">https://theunderfloorheatingsite.co.uk/?post_type=product&#038;p=1015990</guid>

					<description><![CDATA[<p>[block id="16mm-chipboard-short-description"]</p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/foiled-chipboard-underfloor-heating-overlay-boards-1200mm-or-2400mm-x-600mm-x-22mm-for-12mm-or-16mm-pipe-full-tg4/">Foiled Underfloor Heating Chipboard Pre-Routed 22mm thick 600mm wide</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Underfloor Heating Boards &#8211; grooved chipboard for underfloor heating 22mm pre routed</h2>
<ul>
<li><strong>Tongue and groove for faster installation all the way around &#8211; true TG4</strong></li>
<li><strong>P5 Moisture Resistant Chipboards</strong></li>
<li><strong>1.44m2 Per Board for use with 12mm or 16mm Pipe Only </strong></li>
<li><strong>Routed with 150mm or 200m centres</strong></li>
<li><strong>Feed pipes typically run underneath</strong></li>
<li><strong>A 6mm cement board must be glued and screwed as per manufacturers instruction to bring back structural strength before fitting finished floors</strong></li>
<li><strong>Options for foiled and bonded thermal or acoustic insulation</strong></li>
</ul>
<p><strong>Technical Data:</strong></p>
<ul>
<li><strong>Thermal Conductivity</strong>: 0.033 W/mK (when bonded to XPS)</li>
<li><strong>Moisture Absorption:</strong> 0.6%</li>
<li><strong>Widths Available:</strong> 600mm</li>
<li><strong>Lengths Available:</strong> 1200mm / 2400mm</li>
<li><strong>Dimensional Tolerances:</strong> (+/-1mm)</li>
<li><strong>Compressive Strength:</strong> 300kPa, 500kPa</li>
</ul>
<p>Moisture resistant routed chipboard, available standard, foiled, or bonded to additional thermal or acoustic insulation. Our Chip-UFH Board is highly conductive which allows for an even spread of heat throughout the floor. System should be completed with 6mm cement backer board, further details available on request.</p>
<p><strong>INSTALLATION</strong> Chip-UFH Board is typically installed directly onto floor joists (usually insulated in-between), utilising standard chipboard screws and joint adhesive.</p>
<p><strong>FINISHING</strong> A 6mm cement overlay board should be applied using co-polymer eva glue and screws prior to the application of any floor finishes. Laminates, hardwood flooring and carpets should be applied using a suitable underlay as per manufactures instructions. LVT type flooring normally requires a 2-3mm levelling compound applied to the cement backer board to smooth out join lines and screw heads.</p>
<p><strong>SUITABILITY </strong>Chip-UFH Board is suitable for new build or retro fit installations, and the standard pattern board is normally available from stock.</p>
<p><span style="color: #f99b1c;"><strong>PLEASE NOTE: DELIVERY OF THESE BOARDS MAY TAKE 4-5 WORKING DAYS</strong></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://theunderfloorheatingsite.co.uk/shop/insulation-overlay-boards/underfloor-heating-chipboard-overlay-boards/foiled-chipboard-underfloor-heating-overlay-boards-1200mm-or-2400mm-x-600mm-x-22mm-for-12mm-or-16mm-pipe-full-tg4/">Foiled Underfloor Heating Chipboard Pre-Routed 22mm thick 600mm wide</a> appeared first on <a href="https://theunderfloorheatingsite.co.uk">The Underfloor Heating Site</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 

Served from: theunderfloorheatingsite.co.uk @ 2026-05-12 23:29:38 by W3 Total Cache
-->